CONTACTORS TYPE TADN
FIELD
DISCHARGE CONTACTORS TYPE TADN FROM 46 TO 6000 AMPS UP TO 1000V
These contactors are made from
the combination of the two special executions TDN and TAN, and are fitted as follows:
a) Main contacts,
open when the contactor is open, suitable to energize or deenergize the field circuit of
generators, motors, synchronous condensers or exciters;
b) Discharge contacts, closed when the contactor is
open, suitable to short-circuit, through a proper discharge resistor, the field circuit at
the instant preceding the opening of the main contacts. Moreover, when the contactor is
closing, the discharge contacts disconnect the field circuit from the discharge resistor,
at the instant following the closing of the main contacts. When used for direct-current
generators operation, the discharge contacts are adjusted so that they open before the
main contacts close and, viceversa, close after the main contacts open;
c) The control circuit is usually of the
<<TA>> type with mechanical latct, but can also be of normal type in D.C. as
well as in A.C.

The most frequent type of
connection, in the case of synchronous generators excited by static exciters, is the one
shown in the figured diagram and the characteristics these contactors have to perform are
the following.
(Table N°14)
| General
Characteristics |
Characteristics
of the Main Contacts
(2 poles) |
Characteristics
of Discharge Contacts (1 pole) |
TADN
Size |
Vn |
V' |
In |
Vcc |
I'cc |
Icc |
ICC0,5 |
Ind |
Iccd |
Ichd |
ID 15'' |
| [V] |
[V] |
[A] |
[V] |
[A] |
[A] |
[A] |
[A] |
[A] |
[A] |
[A] |
| 85 |
600 |
700 |
85 |
1000 |
900 |
800 |
4000 |
85 |
400 |
2500 |
1000 |
| 125 |
600 |
700 |
125 |
1000 |
1200 |
1000 |
5000 |
125 |
600 |
3000 |
1200 |
| 190 |
600 |
700 |
190 |
1000 |
2000 |
1500 |
8000 |
190 |
1000 |
4000 |
2000 |
| 270 |
750 |
700 |
270 |
1000 |
3000 |
2000 |
15000 |
270 |
2500 |
6000 |
3000 |
| 350 |
750 |
700 |
350 |
1000 |
4000 |
3000 |
16000 |
350 |
3000 |
7000 |
3500 |
| 550 |
750 |
700 |
550 |
1000 |
6000 |
4000 |
20000 |
550 |
5000 |
8000 |
5500 |
| 650 |
750 |
700 |
650 |
1000 |
7000 |
5000 |
20000 |
650 |
6000 |
10000 |
6500 |
| 800 |
1000 |
700 |
800 |
1000 |
8000 |
6000 |
25000 |
800 |
8000 |
12000 |
7000 |
| 1000 |
1000 |
700 |
1000 |
1000 |
10000 |
8500 |
25000 |
1000 |
10000 |
15000 |
8000 |
| 1250 |
1000 |
700 |
1250 |
1000 |
15000 |
10000 |
35000 |
1250 |
10000 |
15000 |
10000 |
| 1600 |
1000 |
700 |
1600 |
1000 |
20000 |
15000 |
50000 |
- |
- |
- |
- |
| 2000 |
1000 |
700 |
2000 |
1000 |
20000 |
15000 |
60000 |
- |
- |
- |
- |
| 3000 |
1000 |
700 |
3000 |
1000 |
20000 |
15000 |
80000 |
- |
- |
- |
- |
| 3200* |
1200 |
1500 |
3200 |
2000 |
15000 |
15000 |
100000 |
- |
- |
- |
- |
| 4000* |
1200 |
1500 |
4000 |
2000 |
15000 |
15000 |
100000 |
- |
- |
- |
- |
| 6000* |
1200 |
1500 |
6000 |
2000 |
15000 |
15000 |
100000 |
- |
- |
- |
- |
*Version FSS with
double interruption on each main pole
- For higher voltage please ask our technical department
- For TADN size > 1250, use pole R800 or R1000
General Characteristics| Electrical
Characteristics | Overall Dimensions | Contactors type
TAN | Contactors type TDN | Contactors
type NF, NFS, NHF | Contactors type CN
HOME |